當使用MASS SCALING,D3HSP檔案有以下內容 ========================================= problem cycle = 673005 time = 4.0000E-03 added low frequency mass = 0.0000E+00 percentage increase = 0.0000E+00 added high frequency mass = 5.8598E-11 percentage increase = 2.8869E-06 ============================================== 但GLSTAT中 dt of cycle 673005 is controlled by dt2ms time........................... 3.99999E-03 time step...................... 4.50000E-09 kinetic energy................. 6.83053E+03 internal energy................ 2.09225E+04 spring and damper energy....... 1.20000E-19 hourglass energy .............. 1.34276E-01 system damping energy.......... 0.00000E+00 sliding interface energy....... -6.80041E+03 external work.................. 0.00000E+00 eroded kinetic energy..........0.00000E+00 eroded internal energy.........0.00000E+00 eroded hourglass energy........ 0.00000E+00 total energy................... 2.09528E+04 total energy / initial energy.. 1.45798E+00 energy ratio w/o eroded energy. 1.45798E+00 global x velocity.............. 1.03716E+03 global y velocity.............. 8.07692E+01 global z velocity.............. 1.99293E+03 time per zone cycle.(nanosec).. 36 number of shell elements that reached the minimum time step.. 0 added mass..................... 0.00000E+00 percentage increase............ 0.00000E+00 (1)這樣到底有沒有增加重量? (2)如何得知受到dt2ms影響的元素有哪些?在哪個PART?
提問者:
LS-DYNA新手
提問於: 2019-08-14 09:30:47
最後修改時間: 2019-08-14 09:30:47


最佳解答
3
Votes
依您的訊息來看,您應該是使用了*CONTROL_TIMESTEP的IMSCL (selective mass scaling flag)。
(1) 有增加質量,且是增加在high frequency mode元素上;因GLSTAT沒有包含high frequency mode,所以顯示質量增加為零。 mass scaling的目的在於增加explicit的timestep,而selective mass scaling針對所選擇的零件,依frequency modes(只會影響high frequencies),做更準確的mass scaling。 一般影響time step較多的是high frequency mode元素,而變形或kinetic energy常發生在low frequency mode元素,藉此將mass scaling重點施加在high frequency mode的元素上。所以整體而言使用selective mass scaling所增加的質量會比conventional mass scaling較低,也因此物理上較準確,但相對的需要較多CPU與記憶體資源且計算時間會比後者多。建議在IMSCL輸入小於0的值,可以選擇要selective mass scaling的part set ID,其計算結果也較其他整體的解決方法準確。
(2) GLSTAT僅包含conventional mass scaling的部分所增加的質量,也就是low frequency的部分;
D3HSP和MATSUM則將conventional mass scaling 和 selective mass scaling的部分都包含在資料裡。
在MATSUM有輸出元素增加的質量,可以讓你分別得到整個模型及個別零件的added mass和時間的關係圖; 從後處理,可顯示零件所增加的質量。(可參考lsdyna mass scaling介紹,第五段)
回覆者: Christine
時間: 2019-08-14 09:51:03

1 answers